High-frequency and brief-pulse stimulation pulses terminate cortical electrical stimulation-induced afterdischarges

(整期优先)网络出版时间:2017-06-16
/ 1
Brief-pulsestimulationat50Hzhasbeenshowntoterminateafterdischargesobservedinepilepsypatients.However,theoptimalpulsestimulationparametersforterminatingcorticalelectricalstimulation-inducedafterdischargesremainunclear.Inthepresentstudy,weexaminedtheeffectsofdifferentbrief-pulsestimulationfrequencies(5,50and100Hz)oncorticalelectricalstimulation-inducedafterdischargesin10patientswithrefractoryepilepsy.Resultsdemonstratedthatbrief-pulsestimulationcouldterminatecorticalelectricalstimulation-inducedafterdischargesinrefractoryepilepsypatients.Inconclusion,(1)abrief-pulsestimulationwasmoreeffectivewhentheafterdischargedidnotextendtothesurroundingbrainarea.(2)Ahigherbrief-pulsestimulationfrequency(especially100Hz)wasmorelikelytoterminateanafterdischarge.(3)Alowcurrentintensityofbrief-pulsestimulationwasmorelikelytoterminateanafterdischarge.